Table Of Content:
- EMC DES-6321 Dumps Pdf
- EMC DES-6321 Dumps Youtube
- EMC DES-6321 Exam Practice Test
- EMC Discount Code 2021
Share EMC DES-6321 exam practice questions and answers from Lead4Pass latest updated DES-6321 dumps free of charge. Get the latest uploaded DES-6321 dumps pdf from google driver online. To get the full EMC DES-6321 dumps PDF or dumps VCE visit: https://www.leads4pass.com/des-6321.html (Q&As: 196). all EMC DES-6321 exam questions have been updated, the answer has been corrected!
Make sure your exam questions are real and effective to help you pass your first exam!
[EMC DES-6321 Dumps pdf] Latest EMC DES-6321 Dumps PDF collected by Lead4pass Google Drive:
https://drive.google.com/file/d/1hVHIp-XFoLyGRr1LqzO16ONGo-53ZG60/
Latest Update EMC DES-6321 Exam Practice Questions and Answers Online Test
QUESTION 1
Which license bundled with VxRail is restricted to deployments with an Embedded vCenter?
A. vRealize Log Insight
B. vSAN ELA
C. Dell EMC SRS
D. ESXi vSphere
Correct Answer: A
QUESTION 2
An all-flash VxRail cluster has just been deployed. When attempting to enable compression, the option is grayed out.
What is the cause of this situation?
A. “Add disks to storage” is set to manual
B. Erasure Coding is not enabled
C. Erasure Coding is not disabled
D. “Add disks to storage” is set to automatic
Correct Answer: D
QUESTION 3
Which port configuration is invalid on the integrated NIC of a VxRail node?
A. 2 x 25 GbE SFP28
B. 2 x 10 GbE RJ45
C. 2 x 10 GbE SFP+
D. 2 x 1 GbE RJ45
Correct Answer: D
Reference: https://www.dellemc.com/en-us/collaterals/unauth/technical-guides-support-information/products/convergedinfrastructure/h15300-vxrail-network-guide.pdf (10)
QUESTION 4
Which settings would be expected to find in the VxRAIL_SYSTEM-STORAGE=PROFILE?
A. FTT=2 Object space reservation (%) – 0
B. FTT = 1 Object space reservation (%) – 100
C. FTT = 2 Object space reservation (%) – 100
D. FTT = 1 Object space reservation (%) = 0
Correct Answer: B
QUESTION 5
What is the correct command to restart the Loudmouth process on a VxRail node?
A. /usr/lib/vmware-loudmouth/bin/loudmouthc restart
B. systemctl restart vmware-loudmouth
C. /etc/init.d/loudmouth restart
D. /sbin/service loudmouth restart
Correct Answer: C
https://pbradz.wordpress.com/category/vxrail/
QUESTION 6
During a VxRail installation, the deployment fails at 9%. Based on the exhibit, what could be the reason for this failure?
A. Domain name .local is not supported
B. Password field has an extra space
C. vCenter and PSC information is missing
D. Timezone is in an incorrect format
Correct Answer: C
QUESTION 7
When resetting a Dell PowerEdge-based VxRail node to an existing factory image, which boot device should be
selected?
A. BOSS
B. RASRUSB
C. SATADOM
D. IDSDM
Correct Answer: D
Reference: https://www.dell.com/community/VxRail/Reset-VxRail-V470F-node-to-default-factory-configuration/tdp/7171517
QUESTION 8
After initial installation, the vSAN health check is reporting issues. Which action needs to be taken to correct the vSAN
health check error?
A. Upgrade to the latest version of VxRail.
B. Upgrade to the latest driver version.
C. Reset error message to green.
D. Update HCL database and run health check.
Correct Answer: B
QUESTION 9
What is the remote management option for G Series VxRail nodes?
A. RMM
B. iLO
C. iDRAC
D. IPMI/BMC
Correct Answer: D
QUESTION 10
During a VxRail 2 node Cluster deployment, what Is a valid connects option?
A. 4 x 1 GbE
B. 2 x 25 GbE
C. 2 x 10 GbE
D. 4 x 25 GbE
Correct Answer: C
QUESTION 11
When using VxRail Manager, what is the source of information that can help validate good VxRail system post-deployment status?
A. the Last Heartbeat, Last Configuration Sent, Network Environment Settings, Cluster Monitor
B. System Diagnostic, Events, Health Logical View, Health Physical View, Log Bundle
C. MARVIN-Virtual-SAN-Cluster > Manage > Health and Performance
D. MARVIN-Virtual-SAN-Cluster > Monitor > Virtual SAN > Health
Correct Answer: C
QUESTION 12
You are configuring SmartFabric Services on a VxRail running version 4.7X. What is the maximum number of separate
vCenter instances that an OMNI plug-in can be registered within a single fabric?
A. 1
B. 2
C. 5
D. 10
Correct Answer: D
QUESTION 13
During the installation of a new VxRail cluster, where is System Time configured?
A. System BIOS > Miscellaneous Settings
B. iDRAC Settings > System Time
C. System BIOS > System Information
D. iDRAC Settings > System Profile Settings
Correct Answer: A
Lead4Pass EMC Discount Code 2021
For the full EMC DES-6321 exam dumps from Lead4pass DES-6321 Dumps pdf or Dumps VCE visit: https://www.leads4pass.com/des-6321.html (Q&As: 196 dumps)
ps.
Get free EMC DES-6321 dumps PDF online: https://drive.google.com/file/d/1hVHIp-XFoLyGRr1LqzO16ONGo-53ZG60/